RADIATION SYMMETRY
17.5
*
RADIATION SYMMETRY: Define cavity symmetries for radiation heat transfer
analysis.
This option must precede the
*
CYCLIC,
*
PERIODIC, and/or
*
REFLECTION options to specify symmetries
in cavities used for cavity radiation heat transfer analysis.
Product: ABAQUS/Standard
Type: History data
Level: Step
References:
“Cavity radiation,” Section 32.1.1 of the ABAQUS Analysis User ’s Manual
*
CYCLIC
*
PERIODIC
*
REFLECTION
Required parameter:
NAME
Set this parameter equal to a label that will be used to refer to the symmetry reference appearing in
the
*
RADIATION VIEWFA CTOR option.
There are no data lines associated with this option.