RESPONSE SPECTRUM
4. Z-direction cosine of this direction.
5. Factor multiplying the magnitudes i n the response spectr um. Default is 1.0.
Second line (optional):
1. Name of the response spectrum to be used in the second direction.
2. X-direction cosine of this direction. This direction must be at a right angle to the direction
defined above.
3. Y-direction cosine of this direction. This direction mus t be at a right angle to the direction
defined above.
4. Z-direction cosine of this direction. This direction must be at a right angle to the direction
defined above.
5. Factor multiplying the magnitudes i n the response spectr um. Default is 1.0.
Third line (optional):
1. Name of the response spectrum to be used in the third direction.
2. X-direction cosine of this direction. This direction must be at right angles to the two directions
defined above.
3. Y-direction cosine of this direction. This dir ection must be at right angles to the two directions
defined above.
4. Z-direction cosine of this direction. This direction must be at right angles to the two directions
defined above.
5. Factor multiplying the magnitudes i n the response spectr um. Default is 1.0.